148 OLD CONCORD TURNPIKE BARRINGTON, NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708
E-Mail:[email protected] www.seafrost.com
THERMOSTAT CALIBRATION INSTRUCTIONS
Note: Be sure that the unit is operating properly before making any thermostat
adjustments. The sensing bulb must be in excellent thermal contact with the plate or
block.
The range of this control may be changed. To access
the adjustment screw, remove the four mounting
screws on the thermostat panel. Tip the panel forward
and make the adjustment with a torx or small phillips
head screwdriver.
Make small adjustments. Record all adjustments.
If the lowest setting on the thermostat panel is too
cold:
Turn the adjustment screw clockwise. One
360-degree turn will raise the box temperature
approximately 6 degrees f.
If the highest setting on the thermostat panel is too
warm:
Turn the adjustment screw counterclockwise.